Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Braz. j. pharm. sci ; 51(4): 833-837, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778419

ABSTRACT

abstract Ultraviolet spectrophotometric (UV) and Liquid Chromatographic (LC) methods for the determination of mianserin hydrochloride in pharmaceutical formulation were developed and validated. The various parameters, such as specificity, linearity, precision and accuracy were studied according to International Conference on Harmonization (ICH, 2005). For UV method, mianserin hydrochloride was determinate at 278 nm using HCl 0.1 M as the solvent. The response was linear in the concentration range of 20.0 - 140.0 µg/mL (r = 0.9998). Precision data evaluated by relative standard deviation was lower than 2%. The UV method was simple, rapid and low cost. Chromatographic analyses were performed in an Ace C18 column and the mobile phase was composed of methanol, 50 mM monobasic potassium phosphate buffer and 0.3% triethylamine solution adjusted to pH 7.0 with phosphoric acid 10% (85:15). LC method was specific, linear, precise, exact and robust. The results confirmed that the both methods are valid and useful to the routine quality control of mianserin hydrochloride in coated tablets. Statistical analysis by Student´s t-test showed no significant difference between the results obtained by UV and LC methods.


resumo Os métodos por espectrofotometria na região do ultravioleta (UV) e por cromatografia líquida (CL) para determinação do cloridrato de mianserina na forma farmacêutica foram desenvolvidos e validados. Os vários parâmetros, como especificidade, linearidade, precisão e exatidão foram avaliados de acordo com o International Conference on Harmonization (ICH, 2005). Para o método de UV, o cloridrato de mianserina foi determinado utilizando o comprimento de onda de 278 nm e HCl 0,1 M como solvente. A resposta foi linear na faixa de concentração de 20,0 a 140,0 µg/Ml (r = 0,9998). A precisão foi avaliada pelo valor de desvio padrão relativo (DPR) inferior a 2%. O método por UV é simples, rápido e de baixo custo. As análises cromatográficas foram realizadas em uma coluna Ace C18 e a fase móvel foi composta por metanol, tampão fosfato de potássio monobásico 50 mM com 0,3% de trietilamina com o pH ajustado para 7,0 com ácido fosfórico 10% (85:15). O método de CL foi específico, linear, preciso, exato e robusto. Os resultados confirmam que ambos os métodos são válidos e úteis para o controle de qualidade do cloridrato de mianserina em comprimidos revestidos. A análise estatística por teste t de Student não mostrou diferença significativa entre os resultados obtidos para os métodos de UV e CL.


Subject(s)
Spectrophotometry, Ultraviolet , Mianserin/pharmacokinetics , Tablets/pharmacokinetics , /analysis , Chromatography, Liquid
2.
Rev. bras. farmacogn ; 25(3): 219-227, May-June 2015. tab, ilus
Article in English | LILACS | ID: lil-757430

ABSTRACT

AbstractThis study uses high performance liquid chromatography and capillary electrophoresis as analytical tools to evaluate flavonoids in hydrolyzed leaves extracts of Rubus erythrocladus Mart., Rosaceae, and Morus nigra L., Moraceae. For phytochemical analysis, the extracts were prepared by acid hydrolysis and ultrasonic bath and analyzed by high performance liquid chromatography using an ultraviolet detector and by capillary electrophoresis equipped with a diode-array detector. Quercetin and kaempferol were identified in these extracts. The analytical methods developed were validated and applied. Quercetin and kaempferol were quantified in R. erythrocladus, with 848.43 ± 66.68 μg g-1 and 304.35 ± 17.29 μg g-1, respectively, by HPLC-UV and quercetin, 836.37 ± 149.43 μg g-1, by CE-DAD. In M. nigra the quantifications of quercetin and kaempferol were 2323.90 ± 145.35 μg g-1 and 1446.36 ± 59.00 μg g-1, respectively, by HPLC-UV and, 2552.82 ± 275.30 μg g-1 and 1188.67 ± 99.21 μg g-1, respectively, by CE-DAD. The extracts were also analyzed by ultra-performance liquid chromatography coupled with a diode-array detector and mass spectrometer (MS), UPLC-DAD/MS.

3.
Journal of Pharmaceutical Analysis ; (6): 137-141, 2015.
Article in Chinese | WPRIM | ID: wpr-671970

ABSTRACT

A dissolution test for fesoterodine low dose extended-release tablets using liquid chromato-graphic (LC) method equipped with a C18 monolithic column was developed and validated. LC system was operated isocratically at controlled temperature (40 1C) using a mobile phase of acetonitrile:methanol:0.03 M ammonium acetate (pH 3.8) (30:15:55, v/v/v), run at a flow rate of 1.5 mL/min and detected at 208 nm. The best dissolution conditions for this formulation were achieved using a USP apparatus 2 (paddle) at 100 rpm and 900 mL of phosphate buffer at pH 6.8 as the dissolution medium. Validation parameters such as the specificity, linearity, accuracy, precision, and robustness were evaluated according to international guidelines, giving results within the acceptable range. The kinetic parameters of drug release were also investigated using model-dependent methods and the dissolution profiles were best described by the Higuchi model. The validated dissolution test can be applied for quality control of this formulation.

4.
Acta sci., Health sci ; 36(2): 235-241, jun.-dez. 2014. ilus, tab
Article in English | LILACS | ID: biblio-833147

ABSTRACT

Current study develops and validates a dissolution test for Prasugrel hydrochloride 10 mg in coated tablets. After sink condition, filters and drug stability were evaluated, the discriminatory dissolution conditions were achieved with a USP apparatus 1 (basket) at 50 rpm stirring speed and 900 mL of 0.01 M HCl as dissolution medium. The UV spectrometric method at 220 nm was performed and validated for the determination of Prasugrel. The parameters specificity, linearity, accuracy, precision and robustness were evaluated according to international protocols. UV method and dissolution test proposed in current analysis may be applied for quality control of coated tablets containing Prasugrel since there is no official monograph for this drug.


O objetivo do presente estudo foi desenvolver e validar um teste de dissolução para cloridrato de Prasugrel 10 mg presente em comprimidos revestidos. Após avaliação da condição sink, filtros e estabilidade da droga, condições discriminatórias foram alcançadas utilizando equipamento USP 1 (cesta) em velocidade de 50 rpm e meio de dissolução composto por HCL 0,01 M . Foi desenvolvido e validado método de espectrofotometria na região do ultravioleta (UV) a 220 nm para a determinação de Prasugrel. Foram avaliados os parâmetros como especificidade, linearidade, exatidão, precisão e robustez de acordo com os guias internacionais. O método UV e o teste de dissolução propostos neste estudo podem ser aplicados para o controle de qualidade de comprimidos revestidos contendo Prasugrel, uma vez que não há monografia oficial para este fármaco.


Subject(s)
Quality Control , Spectrophotometry, Ultraviolet , Validation Study , Dissolution
5.
Braz. j. pharm. sci ; 46(2): 179-186, Apr.-June 2010. ilus, tab
Article in English | LILACS | ID: lil-564883

ABSTRACT

A dissolution test for tablets containing 100 mg of lamotrigine was developed and validated. The dissolution test was applied to compare the dissolution profile of Neural® with the reference product Lamictal®. The analysis procedure was carried out using a simple ultraviolet method at 267 nm. After the determination of solubility and sink conditions, the parameters selected were paddles at 50 rpm, 900 mL of 0.01 M hydrochloric acid, and 30 minutes duration (single point). This method was validated for specificity, linearity, accuracy, precision and robustness. Lamotrigine stability was also evaluated in dissolution medium.


A finalidade deste estudo foi desenvolver e validar um método de dissolução para o fármaco lamotrigina na forma farmacêutica comprimido. Este método também foi utilizado para comparar o perfil de dissolução entre o Neural® e o produto de referência Lamictal®. O procedimento analítico foi realizado utilizando-se espectrofotometria de absorção no ultravioleta (267 nm) como forma de quantificação do fármaco. Após a determinação da solubilidade e das condições sink, os parâmetros selecionados foram: pás (50 rpm), 900 mL de ácido clorídrico 0.01 M e o tempo de 30 minutos (único ponto). Este método foi validado através da especificidade, linearidade, exatidão, precisão e robustez. A estabilidade da lamotrigina também foi avaliada no meio de dissolução.


Subject(s)
Anticonvulsants/analysis , Tablets/chemistry , Technological Development/analysis , Dissolution/methods , Spectrophotometry, Ultraviolet/methods , Pharmaceutical Preparations , Quality Control
6.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 43(4): 563-570, out.-dez. 2007. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-479325

ABSTRACT

A carbocisteína é um agente mucolítico utilizado como adjuvante no tratamento de infecções do trato respiratório. A qualidade, segurança e eficácia do medicamento durante o seu prazo de validade são responsabilidades da indústria farmacêutica. A validade pode ser determinada através de estudos de estabilidade acelerados, nos quais fatores extrínsecos provocam a degradação do produto. De acordo com Arrhenius, existe uma relação entre temperatura e cinética química. Desta forma, amostras do produto foram expostas a condições drásticas: 40, 50, 60 e 70 ºC. O método de doseamento do xarope de carbocisteína foi validado podendo ser aplicado nas avaliações de rotina do controle de qualidade e no estudo de estabilidade deste produto. O prazo de validade proposto para o xarope de carbocisteína, calculado através da equação de Arrhenius, para a temperatura de 25 ºC foi de 240,9 dias. No entanto, foi observada diferença entre o prazo proposto e a validade usualmente praticada para este produto. Este estudo, ainda, demonstrou a presença de picos endógenos, que precisam ser melhor estudados a fim de se confirmar a presença de produtos de degradação.


Carbocysteine is a mucolytic agent in adjunctive therapy of respiratory tract infections. The pharmaceutical industry is responsible for quality, safety and efficiency of the product during its shelf life. Shelf life can be determinated through an accelerated stability study where the degradation of the drug is managed with the extrinsic factors. According to Arrhenius, there is a relationship between temperature and chemical kinetic, so, the samples were exposed to drastic conditions at 40, 50, 60 and 70 ºC. The syrup assay method has been validated and it may be applied to analysis of carbocysteine syrup in routine quality control and stability studies. Through Arrhenius equation the proposed shelf life of carbocysteine syrup was 240.9 days when the dosage form is stored in appropriated conditions, 25 ºC. However difference was found between the proposed shelf life and the usual shelf life of this drug. In addition, this study has showed the presence of endogenous peaks that must be better evaluated to confirm or not the presence of degradation products.


Subject(s)
Carbocysteine/pharmacology , Respiratory Tract Infections/metabolism , Respiratory Tract Infections/drug therapy , Drug Stability , Drug Stability
7.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 36(1): 97-110, jan.-jun. 2000. ilus
Article in Portuguese | LILACS | ID: lil-276139

ABSTRACT

Como quase todas as boas idéias, a eletroforese capilar (CE) é fácil e eficiente. O equipamento é constituído por componentes simples e perfeitamente controlados, proporcionando a reprodutibilidade e a confiabilidade requeridas para a validação dos métodos analíticos empregados no controle de qualidade de medicamentos. Para muitas moléculas importantes, a CE proporciona ótimos resultados quando comparada com outras técnicas. Para a separação de alguns compostos com estruturas muito complexas, tais como princípios ativos altamente polares, enantiômeros e compostos básicos, a CE oferece vantagens muito significativas em relação à cromatografia a líquido de alta eficiência. A CE permite, ainda, fácil validação de ensaios quantitativos para determinação de traços de impurezas, assim como para a determinação quantitativa de vários compostos em fluidos biológicos


Subject(s)
Electrophoresis, Capillary , Quality of Homeopathic Remedies , Chemistry, Pharmaceutical , Quality Control
8.
Säo Paulo; s.n; 2000. 220 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-289810

ABSTRACT

A cefalexina é um antibiótico cefalosporânico de primeira geração sintetizado no final da década de setenta e utilizado principalmente no tratamento de infecções do sistema respiratório, causadas por microrganismos Gram positivos. Devido a sua estabilidade em meio ácido, as preparações farmacêuticas contendo cefalexina apresentam excelente absorção por via oral, sendo disponibilizadas no comércio na forma de comprimidos, cápsulas e suspensões orais. Apesar do amplo emprego deste antibiótico existem poucos dados na literatura a respeito da estabilidade da cefalexina em preparações farmacêuticas. Particularmente, em relação às suspensões orais, o estudo de estabilidade torna-se mais difícil devido à complexidade da formulação e às inúmeras interções que podem ocorrer entre o fármaco e os excipientes utilizados...


Subject(s)
Animals , Mice , Cephalexin/pharmacokinetics , Cephalosporin Resistance/immunology , Drug Stability , Enterobacter/metabolism , Pharmaceutical Preparations , Drug Stability , Chromatography, High Pressure Liquid/methods , Differential Thermal Analysis , Electrophoresis, Capillary , Suspensions
SELECTION OF CITATIONS
SEARCH DETAIL